Is it worth to perform preoperative MRI for breast cancer after mammography, tomosynthesis and ultrasound?

González-Huebra I (1), Elizalde A (2), García-Baizán A (3), Calvo M (4), Ezponda A (5), Martínez-Regueira F (6), Pina L (7).

(1) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(2) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(3) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(4) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(5) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(6) Department of General Surgery, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.
(7) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Navarra, Spain.

Revisão:Magnetic Resonance Imaging

Data: 1/Abr/2019

Area de Patología da Mama Radiología [ES]

BACKGROUND:

The use of preoperative breast MRI remains controversial despite being the most sensitive technique for the detection of breast malignancies.

PURPOSE:

To evaluate the benefit of preoperative breast MRI after performing the three conventional techniques (DM, US, DBT). To analyze the influence of breast density in the sensitivity of the different imaging techniques.

MATERIAL AND METHODS:

Retrospective review of 280 histologically confirmed breast cancers in 192 women. We reviewed the medical records and evaluated the change of treatment induced by MRI. Also, we assessed the reports of DM and the combination of the different imaging techniques, and categorized them according to ACR density (a-d) and as negative (BI-RADS 1-3) or positive (BIRADS 4 or 5). The gold standard was the pathologic assessment of the surgical specimen. The sensitivity of the different techniques was compared using McNemar test.

RESULTS:

Among these 192 women the use of MRI did not significantly increase the mastectomy rate (from 16.6% to 17.6%; p = 0.5). The addition of any technique demonstrated a higher sensitivity than DM alone. The sensitivity of DM alone was 52.5% while using all the techniques, including MRI, was 94.3% (p < 0.001). Regardless of breast density pattern, the addition of any technique significantly increased the sensitivity of DM (p < 0.001).

CONCLUSIONS:

The addition of MRI to the three conventional techniques increased the sensitivity but did not significantly modify the rate of mastectomies. Additional techniques increased the sensitivity of DM in both dense and non-dense breasts.

CITAÇÃO DO ARTIGO   Magn Reson Imaging. 2019 Apr;57:317-322. doi: 10.1016/j.mri.2018.12.005. Epub 2018 Dec 20

talvezlhe interesse

QUE TECNOLOGIA UTILIZAMOS? 

A Clínica é o hospital privado com maiores recursos tecnológicos de Espanha, tudo num único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OS NOSSOS
PROFISSIONAIS

Os profissionais da Clínica realizam um trabalho contínuo de investigação e formação, sempre em benefício do paciente.

Imagen profesionales de la Clínica Universidad de Navarra

RAZÕES PARA VIR
À CLÍNICA

Conheça porque é que somos diferentes em relação a outros centros sanitários. Qualidade, rapidez, comodidade e resultados.

Imagen del edificio de la Clínica Universidad de Navarra