Study of myocardial viability using single-photon emission computed tomography with 201-thallium and re-injection in 4 series (early and late images

García Velloso M.J., Coma Canella I., Gámez Cenzano C., Alegría Ezquerra E., Villas Tomé A., Calabuig Nogués J., Richter Echevarría J.A.
Servicio de Medicina Nuclear, Facultad de Medicina, Universidad de Navarra, Pamplona.

Revista: Revista Española de Cardiología

Fecha: 01/01/1998

Cardiología Medicina Nuclear

OBJECTIVE
The present study was designed to determine whether 24-hour imaging after thallium reinjection or imaging obtained shortly after reinjection provides better results regarding reversibility of fixed perfusion defects observed in conventional stress-redistribution imaging.

PATIENTS AND METHODS
We studied 24 patients undergoing stress-redistribution thallium tomography with fixed defects (15 exercise, 6 adenosine, 3 dobutamine). All patients had coronary angiography and 17 a history of myocardial infarction. After obtaining the redistribution images, 1 mCi thallium was injected at rest, and images were acquired at 30 minutes and 24 hours after reinjection. The tomograms obtained were divided into 12 segments and analyzed quantitatively.

RESULTS
Of the 190 abnormal segments on the stress images, 53 (28%) demonstrated improved thallium uptake on redistribution images and 137 had persistent defects. Shortly after reinjection, 33 (24%) segments had improved thallium uptake and 104 had persistent defects, 29 (28%) of which showed further improvement in the 24-hour study. In patients with myocardial infarction, of the 36 fixed severe defects, 9 (25%) had improved thallium uptake shortly after reinjection, increasing activity from 36 +/- 10% to 53 +/- 8%, and 22 (61%) defects improved at 24 hours, increasing activity from 37 +/- 8% to 56 +/- 6%. Therefore, 13 irreversible segments in the short-term study after reinjection were reversible on 24-hour images.

CONCLUSION
These data indicate that 24-hour imaging after thallium reinjection provides better results regarding reversibility of fixed perfusion defects observed in conventional stress-redistribution imaging than imaging obtained shortly after reinjection.

CITA DEL ARTÍCULO  Rev Esp Cardiol. 1998;51 Suppl 1:38-44

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra