Publicaciones científicas

Primary graft failure after heart transplantation. Successful recovery with pneumatic biventricular assistance.

Fernández A.L., Herreros J.M., Llorens R., Martínez A., Panizo A., Manito N.
Departamento de Cardiología y Cirugía Cardiovascular, Clínica Universitaria de Navarra, Pamplona, Spain

Revista: The International Journal of Artificial Organs

Fecha: 01/05/1996

Cardiología Cirugía Cardíaca Anatomía Patológica

A 41-year-old male underwent orthotopic heart transplantation complicated by intraoperative acute allograft failure.

The patient required immediate placement of a pneumatic biventricular assist device which was kept for 49 days until graft recovery resulted in successful explantation of the device. The patient was discharged from hospital on postoperative day 112.

Management of primary cardiac allograft failure with mechanical ventricular assistance is discussed.

CITA DEL ARTÍCULO  Int J Artif Organs. 1996 May;19(5):307-10