Dual-source CT in heart transplant recipients: quantification of global left ventricular function and mass

Bastarrika, Gorka MD, PhD (1); Arraiza, Maria MD (1); De Cecco, Carlo Nicola MD (3); Broncano, Jordi MD (1); Mastrobuoni, Stefano MD, PhD (2); Ubilla, Matias MD (2); Pueyo, Jesus C. MD, PhD (1); Rabago, Gregorio MD (2)
Institution Departments of (1) Radiology
(2) Cardiovascular Surgery, Clinica Universitaria, Universidad de Navarra
(3) Department of Radiology, Universita' di Roma "Sapienza," Ospedale Sant' Andrea.

Revista: Journal of Thoracic Imaging

Fecha: 01/05/2009

Cirugía Cardíaca Radiología

OBJECTIVE
To evaluate reliability of global left ventricular (LV) function and mass quantification in heart transplant recipients undergoing cardiac dual-source computed tomography examinations by means of manual contour tracing and using a region-growing-based semiautomatic segmentation analysis software tool.

MATERIALS AND METHODS
Twenty-six consecutive heart transplant recipients undergoing cardiac dual-source computed tomography examinations with tube current modulation were included. Double-oblique short-axis 8-mm slice thickness multiphase image reconstructions were used for manual contouring and axial 0.75 mm slices were used for the semiautomated segmentation. LV ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, and myocardial mass were assessed by both segmentation methods. Length of time needed for manual contour tracing and for the semiautomated software was recorded. Contrast-to-noise ratio was calculated in end-diastolic and end-systolic images.

RESULTS
No statistically significant differences were observed in LV functional parameters derived from semiautomatic contour detection algorithm as compared with manual contouring, with excellent agreement (concordance-correlation coefficient >or=0.80). The semiautomated contour detection algorithm overestimated LV mass (mean difference 12.84+/-3.39) (P<0.001). The evaluated software allowed to quantify LV parameters in a significantly shorter period of time (mean difference 201.68+/-121.98 s, P<0.001). Contrast-to-noise ratio in end-systole and end-diastole statistically differed (mean difference 5.29+/-2.94 Hounsfield units; P<0.01) but did not significantly hamper the semiautomated segmentation.

CONCLUSIONS
Objective quantification of LV volumes using the evaluated semiautomated segmentation software is precise, reproducible, and time effective.

CITA DEL ARTÍCULO  J Thorac Imaging. 2009 May;24(2):103-9

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra