Computational particle-haemodynamics analysis of liver radioembolization pretreatment as an actual treatment surrogate

Aramburu J (1), Antón R (1,2), Rivas A (1), Ramos JC (1), Sangro B (2,3,4), Bilbao JI (2,3).

(1) Thermal and Fluids Engineering Division, Mechanical Department, Tecnun-University of Navarra, P° Manuel Lardizabal 13, 20018, Donostia-San Sebastián, Spain.
(2) Instituto de Investigación Sanitaria de Navarra (IdiSNA), Av. Pío XII 36, 31008, Pamplona, Spain.
(3) Clínica Universidad de Navarra, Av. Pío XII 36, 31008, Pamplona, Spain.
(4) Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBEREHD), Av. Pío XII 36, 31008, Pamplona, Spain.

Revisão:International Journal for Numerical Methods in Biomedical Engineering

Data: 1/Fev/2017

Radiología [ES] Hepatologia

RESUMO

Liver radioembolization (RE) is a treatment option for patients with unresectable and chemorefractory primary and metastatic liver tumours. RE consists of intra-arterially administering via catheter radioactive microspheres that locally attack the tumours, sparing healthy tissue.

Prior to RE, the standard practice is to conduct a treatment-mimicking pretreatment assessment via the infusion of 99m Tc-labelled macroaggregated albumin microparticles.

The usefulness of this pretreatment has been debated in the literature, and thus, the aim of the present study is to shed light on this issue by numerically simulating the liver RE pretreatment and actual treatment particle-haemodynamics in a patient-specific hepatic artery under two different literature-based cancer scenarios and two different placements of a realistic end-hole microcatheter in the proper hepatic artery.

The parameters that are analysed are the following: microagent quantity and size (accounting for RE pretreatment and treatment), catheter-tip position (near the proper hepatic artery bifurcation and away from it), and cancer burden (10% and 30% liver involvement).

The conclusion that can be reached from the simulations is that when it comes to mimicking RE in terms of delivering particles to tumour-bearing segments, the catheter-tip position is much more important (because of the importance of local haemodynamic pattern alteration) than the infused microagents (i.e. quantity and size).

Cancer burden is another important feature because the increase in blood flow rate to tumour-bearing segments increases the power to drag particles. These numerical simulation-based conclusions are in agreement with clinically observed events reported in the literature.

CITAÇÃO DO ARTIGO  Int J Numer Method Biomed Eng. 2017 Feb;33(2). doi: 10.1002/cnm.2791

talvezlhe interesse

QUE TECNOLOGIA UTILIZAMOS? 

A Clínica é o hospital privado com maiores recursos tecnológicos de Espanha, tudo num único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OS NOSSOS
PROFISSIONAIS

Os profissionais da Clínica realizam um trabalho contínuo de investigação e formação, sempre em benefício do paciente.

Imagen profesionales de la Clínica Universidad de Navarra

RAZÕES PARA VIR
À CLÍNICA

Conheça porque é que somos diferentes em relação a outros centros sanitários. Qualidade, rapidez, comodidade e resultados.

Imagen del edificio de la Clínica Universidad de Navarra