PUBLICAÇÕES científicas

Volume of high-dose regions and likelihood of locoregional control after perioperative high-dose-rate brachytherapy: Do hotter implants work better?

Martínez-Monge R1, Cambeiro [ES] 2; Ramos LI2, Olarte A2, Valtueña G2, San-Julián M3, Alcalde J [ES]4, Naval-Gías L5, Jurado M6 1Department of Radiation Oncology, Clínica Universidad de Navarra, Pamplona, Navarre, Spain. 2Department of Radiation Oncology, Clínica Universidad de Navarra, Pamplona, Navarre, Spain. 3Department of Orthopedic Surgery, Clínica Universidad de Navarra, Pamplona, Navarre, Spain. 4Department of Otolaryngology, Clínica Universidad de Navarra, Pamplona, Navarre, Spain. 5Department of Oral Surgery, Clínica Universidad de Navarra, Pamplona, Navarre, Spain. 6Department of Gynecology, Clínica Universidad de Navarra, Pamplona, Navarre, Spain.

Revisão:Brachytherapy

Data: 11/Jun/2014

Cirurgia Ortopédica e Traumatologia [ES] Otorrinolaringologia Oncologia Radioterapêutica Ginecologia e Obstetrícia

PURPOSE
To determine whether perioperative high-dose-rate brachytherapy (PHDRB) implants with larger high-dose regions produce increased locoregional control.

METHODS AND MATERIALS
Patients (n=166) enrolled in several PHDRB prospective studies conducted at the University of Navarre were analyzed. The PHDRB was given to total doses of 16Gy/4 b.i.d. or 24Gy/6 b.i.d. treatments for negative or close/positive margins along with 45Gy/25 Rx of external beam radiation therapy. The histogram-based generalized equivalent uniform dose (EUD) formulism was used to quantify and standardize the dose-volume histogram into 2-Gy equivalents. The region of interest analyzed included: tissue volume encompassed by the prescription isodose of 4Gy (TV100). Routine dose reporting parameters such as physical dose and single-point 2-Gy equivalent dose were used for reference.

RESULTS
After a median followup of 7.4 years (range, 3-12+), 50 patients have failed, and 116 remain controlled at last followup. Overall, EUD was not different in the patients who failed compared with controls (89.1Gy vs. 86.5Gy; p=not significant). When patients were stratified by risk using the University of Navarre Predictive Model, very high-risk patients (i.e., tumors ≥3cm resected with close <1mm/positive margins) had an improved locoregional control with higher EUD values (p=0.028). This effect was not observed in low-, intermediate-, and high-risk University of Navarre Predictive Model categories.

CONCLUSIONS
In very high-risk patients, enlarged high-dose regions can produce a dose-response effect. Routine dose reporting methods such as physical dose and single-point 2-Gy equivalent dose may not show this effect, but it can be revealed by histogram-based EUD assessment.

CITAÇÃO DO ARTIGO    2014 Jun 11. pii: S1538-4721(14)00542-X. doi: 10.1016/j.brachy.2014.05.015. [Epub ahead of print]

talvezlhe interesse

QUE TECNOLOGIA UTILIZAMOS? 

A Clínica é o hospital privado com maiores recursos tecnológicos de Espanha, tudo num único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OS NOSSOS
PROFISSIONAIS

Os profissionais da Clínica realizam um trabalho contínuo de investigação e formação, sempre em benefício do paciente.

Imagen profesionales de la Clínica Universidad de Navarra

RAZÕES PARA VIR
À CLÍNICA

Conheça porque é que somos diferentes em relação a outros centros sanitários. Qualidade, rapidez, comodidade e resultados.

Imagen del edificio de la Clínica Universidad de Navarra