PUBLICAÇÕES científicas

Three-dimensional power Doppler vascular sampling: a new method for predicting ovarian cancer in vascularized complex adnexal masses

Alcázar JL [ES], Mercé LT, García Manero M.
Department of Obstetrics and Gynecology, Clínica Universitaria de Navarra, Avenida Pio XII 36, 31008 Pamplona, Spain.

Revisão:Journal of Ultrasound in Medicine

Data: 1/Mai/2005

Ginecologia e Obstetrícia

OBJECTIVE
The purpose of this study was to explore the role of a new concept (vascular sampling) as a third step to discriminate benign and malignant lesions in B-mode and color Doppler sonographically suggestive adnexal masses.

METHODS
Forty-five women (mean age, 52.3 years; range, 17-82 years) with the diagnosis of complex adnexal masses on B-mode sonography were evaluated using 3-dimensional power Doppler sonography. Four women had bilateral masses. After a morphologic reevaluation was done, color pulsed Doppler sonography was used to obtain flow velocity waveforms, and velocimetric indices were calculated (resistive index, pulsatility index, and peak systolic velocity). Thereafter, 3-dimensional power Doppler sonography was used to assess vascularization of highly suggestive areas (gross papillary projections, solid areas, and thick septations), meaning a focused assessment (sampling) of a suggestive area of the tumor. With a virtual organ computer-aided analysis program, vascular indices (vascularization index, flow index, and vascular flow index) were automatically calculated. A definitive histologic diagnosis was obtained in each case.

RESULTS
Forty masses (82%) were malignant and 9 (18%) were benign. Morphologic evaluation revealed 10 (20%) unilocular solid masses, 20 (41%) multilocular solid masses, and 19 (39%) mostly solid masses. Blood flow was found in all cases. Median vascularization index (15.5% versus 8.2%; P = .002), flow index (33.6 versus 20.8; P = .007), and vascular flow index (5.2 versus 2.3; P = .001) were significantly higher in malignant tumors. No differences were found in resistive index (0.43 versus 0.45; P = .770), pulsatility index (0.62 versus 0.65; P = .694), and peak systolic velocity (15.6 versus 12 cm/s; P = .162).

CONCLUSIONS
Three-dimensional power Doppler vascular sampling seems to be a promising tool for predicting ovarian cancer in vascularized complex adnexal masses. It could be better than conventional color pulsed Doppler imaging.

CITAÇÃO DO ARTIGO  J Ultrasound Med. 2005 May;24(5):689-96

talvezlhe interesse

QUE TECNOLOGIA UTILIZAMOS? 

A Clínica é o hospital privado com maiores recursos tecnológicos de Espanha, tudo num único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OS NOSSOS
PROFISSIONAIS

Os profissionais da Clínica realizam um trabalho contínuo de investigação e formação, sempre em benefício do paciente.

Imagen profesionales de la Clínica Universidad de Navarra

RAZÕES PARA VIR
À CLÍNICA

Conheça porque é que somos diferentes em relação a outros centros sanitários. Qualidade, rapidez, comodidade e resultados.

Imagen del edificio de la Clínica Universidad de Navarra