Publicações científicas

Postural analysis of the test timed-up-and-go in patients with vertigo

Rey-Martínez JA, Boleas-Aguirre MS, Pérez N.
Departamento de Otorrinolaringología, Clínica Universitaria, Facultad de Medicina, Universidad de Navarra

Revisão:Acta Otorrinolaringológica Española

Data: 1/Mar/2005

Otorrinolaringologia

INTRODUCTION AND OBJECTIVES
To characterize and analyze the Timed-up-and-go test in non-fallers patients with peripheral vertigo. To assess if turning to the side of the lesion induces a more intense instability.

MATERIAL AND METHODS
The test was performed after carefully explanation to the patient who was allowed to do some attempts. Postural measurements were the angle and angular speed of trunk sway in roll and pitch. It was done with a special device adapted to the trunk with two sensors specially built for that purpose.

CONCLUSIONS
Dizzy, non-fallers patients perform this test in a period of time considered as normal. Canal paresis influences in roll trunk sway when the patient performs the TUG only when turning to the normal side.

CITAÇÃO DO ARTIGO   Acta Otorrinolaringol Esp. 2005 Mar;56(3):107-11

talvezlhe interesse

QUE TECNOLOGIA UTILIZAMOS? 

A Clínica é o hospital privado com maiores recursos tecnológicos de Espanha, tudo num único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OS NOSSOS
PROFISSIONAIS

Os profissionais da Clínica realizam um trabalho contínuo de investigação e formação, sempre em benefício do paciente.

Imagen profesionales de la Clínica Universidad de Navarra

RAZÕES PARA VIR
À CLÍNICA

Conheça porque é que somos diferentes em relação a outros centros sanitários. Qualidade, rapidez, comodidade e resultados.

Imagen del edificio de la Clínica Universidad de Navarra