OBJECTIVES: the purpose of this study was to assess the diagnostic performance of extended transvaginal sonography for diagnosing deep infiltrating endometriosis.

METHODS: A prospective study was conducted comprising 51 women (mean age, 32.9 years; range, 23-43 years) with suspected deep infiltrating endometriosis based on clinical symptoms. All women underwent extended transvaginal sonography, which included assessment of 2 pelvic compartments (anterior compartment: bladder and distal ureters; and posterior compartment: posterior vaginal fornix, retrocervical area, pouch of Douglas, and rectosigmoid). The sliding sign for detecting pouch of Douglas obliteration was also assessed. All patients received bowel preparation before sonographic examinations. A single examiner performed all examinations. All women underwent laparoscopic surgery, and histologic confirmation of endometriosis was done. The sensitivity, specificity, positive likelihood ratio (LR+) and negative likelihood ratio (LR-) were calculated.

RESULTS: Some women had more than 1 lesion, giving a total of 55 histologically confirmed lesions (rectosigmoid, n = 13; vagina, n = 5; retrocervical, n = 32; bladder, n = 5). The sensitivity, specificity, and LR+ for rectosigmoid involvement were 100%, 93%, and 14.0, respectively. The sensitivity, specificity, LR+, and LR- for vaginal involvement were 60%, 98%, 30.0, and 0.41. The sensitivity, specificity, LR+, and LR- for retrocervical involvement were 84%, 96%, 19.4, and 0.16. The sensitivity, specificity, and LR- for bladder involvement were 20%, 100%, and 0.80. The sensitivity, specificity, LR+, and LR- of the sliding sign for diagnosing pouch of Douglas obliteration were 89%, 92%, 10.7, and 0.12.

CONCLUSIONS: Except for bladder involvement, extended transvaginal sonography has good diagnostic performance for deep infiltrating endometriosis.

CITA DEL ARTÍCULO  J Ultrasound Med. 2014 Feb;33(2):315-21. doi: 10.7863/ultra.33.2.315.

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra