Additional US or DBT after digital mammography: which one is the best combination?

Elizalde A (1), Pina L (2), Etxano J (2), Slon P (2), Zalazar R (2), Caballeros M (2).
(1) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain 
(2) Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain. 

Revista: Acta Radiologica

Fecha: 01-ene-2016

Radiología

BACKGROUND

Digital mammography (DM) is widespread used for the detection of breast cancer, but its sensitivity drops in dense breasts. It is well known that additional breast ultrasound (US) and digital breast tomosynthesis (DBT) increase the sensitivity of DM. However, to our knowledge, there are no articles comparing the role of both additional techniques.

PURPOSE

To assess the diagnostic performance of DM and the different combinations of DM + additional DBT and DM + additional US in an enriched sample of patients.

MATERIAL AND METHODS

Retrospective study in an enriched sample of 1042 patients. Out of them, 84 patients had histologically proven malignant lesions and 258 patients had benign lesions. Finally 700 patients with normal explorations or benign lesions without biopsy confirmation (but stable for at least 12 months) were included.

All of them underwent DM, US, and DBT examinations that were retrospectively reviewed by one expert radiologist, blinded to the final diagnoses. The DBT examinations were performed using one single view with wide angle (50°).

The reader categorized the cases as benign (BI-RADS 1 or 2) or malignant (BI-RADS 3-5) for DM and the different combination of techniques. The sensitivity (SE) and specificity (SP) were calculated with the PEPI software and the ROC curves of the different techniques and combinations were calculated by using the SPSS 15.0 software.

RESULTS

The SE and SP of DM were 69.05% and 88.20%, respectively. Additional DBT significantly increased the AUC of DM as well as additional US or the combination DM + DBT + US (P < 0.05). However there were no significant differences between the AUC of DM + US and DM + DBT (P = 0.7).

CONCLUSION

Additional US, DBT, or both, in combination with DM, significantly increased the AUC of DM. However, there were no significant differences between DM + DBT and DM + US.

CITA DEL ARTÍCULO  Acta Radiol. 2016 Jan;57(1):13-8. doi: 10.1177/0284185114563641. Epub 2014 Dec 18.

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra