Publicaciones científicas

Simultaneous determination of diosmin and diosmetin in human plasma by ion trap liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry: Application to a clinical pharmacokinetic study

Campanero MA, Escolar M, Perez G, Garcia-Quetglas E, Sadaba B, Azanza JR.
Clinical Pharmacology, University of Navarra Clinic, 31080 Pamplona, Spain.

Revista: Journal of Pharmaceutical and Biomedical Analysis

Fecha: 01/12/2009

Farmacología Clínica

RESUMEN

Diosmetin (3',5,7-trihydroxy-4'-methoxyflavone) is the aglycone of the flavonoid glycoside diosmin (3',5,7-trihydroxy-4'-methoxyflavone-7-ramnoglucoside). Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the simultaneous determination of diosmin and diosmetin in human plasma was developed and validated. Plasma samples were incubated with beta-glucuronidase/sulphatase.

The analytes were isolated by liquid-liquid extraction with tert-butyl methyl ether at pH 2, and separated on a C(18) reversed-phase column using a mixture of methanol/1% formic acid (58:42, v/v) at a flow rate of 0.5ml/min. APCI in the positive ion mode and multiple reaction monitoring (MRM) method was employed. The selected transitions for diosmin, diosmetin and the internal standard (7-ethoxycoumarin) at m/z were: 609.0-->463.0, 301.2-->286.1 and 191, respectively.

A good linearity was found in the range of 0.25-500ng/ml (R(2)>0.992) for both compounds. The intra-batch assay precision (CV) for diosmin and diosmetin ranged from 1.5% to 11.2% and from 2.8% to 12.5%, respectively, and the inter-batch precision were from 5.2% to 11.5% and 8.5% to 9.8%, respectively. The accuracy was well within the acceptable range the accuracies (from -2.7% to 4.2% and -1.6% to 3.5% for diosmin and diosmetin, respectively). The mean recoveries of diosmin, diosmetin and the internal standard were 87.5%, 89.2% and 67.2%. Stability studies showed that diosmin and diosmetin were stable in different conditions.

Finally, the method was successfully applied to the pharmacokinetic study of diosmin in healthy volunteers following a single oral administration (Daflon).

CITA DEL ARTÍCULO  J Pharm Biomed Anal. 2010 Mar 11;51(4):875-81

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra