Photon-emission tomography (SPECT) in the detection of hepatic hemangiomas of small size

Arbizu J, Varela JI, García MJ, Domper M, Ramírez JC, Richter J.
Servicio de Medicina Nuclear, Clínica Universitaria, Facultad de Medicina, Universidad de Navarra

Revista: Revista Española de Enfermedades Digestivas

Fecha: 01/09/1991

Medicina Nuclear

By means of ultrasonography it is possible to detect hepatic lesions of few millimeters, however, it doesn't give a precise diagnosis. The role of planar scintigraphy in the diagnosis of hepatic hemangioma has already been established, although it has limitations which are partially solved by means of SPECT.

46 patients with different pathologies and 9 healthy volunteers have been studied. In the 19 confirmed hemangiomas, planar scintigraphy showed a sensitivity of 73.6% versus 84.2% for SPECT, mostly due to lesions less than 2.5 cm.

Besides that, SPECT allowed a correct visualization of abdominal and intrahepatic major vessels, although lesions less than 1.5 cm are difficult to evaluate.

CITA DEL ARTÍCULO  Rev Esp Enferm Dig. 1991 Sep;80(3):173-7

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra