Publicaciones científicas

Loading dose of Dexdor® and optimal sedation during oral and maxillofacial ambulatory surgery procedures: An observational study

Martinez-Simon A (1), Cacho-Asenjo E (2), Hernando B (2), Honorato-Cia C (2), Naval L (3), Panadero A (2), Nuñez-Cordoba JM (4).
(1) Departamento de Anestesiología, Reanimación y Cuidados Intensivos, Clínica Universidad de Navarra, Pamplona, Navarra, España.
(2) Departamento de Anestesiología, Reanimación y Cuidados Intensivos, Clínica Universidad de Navarra, Pamplona, Navarra, España.
(3) Departamento de Cirugía Oral y Maxilofacial, Clínica Universidad de Navarra, Pamplona, Navarra, España.
(4) Unidad Central de Ensayos Clínicos, Clínica Universidad de Navarra, Pamplona, Navarra, España. 

Revista: Revista Española de Anestesiología y Reanimación

Fecha: 05/11/2016

Anestesia y Cuidados Intensivos

INTRODUCTION:
Dexdor® do not include the possibility of loading dose, which could increase time to achieve adequate sedation for ambulatory procedures. The objective of this study was to evaluate the effect of several loading dose of dexmedetomidine in the time to achieve and maintain an optimal level of sedation and its clinical hemodynamic repercussion.

MATERIAL AND METHODS:
The IRB approved this observational study for patients that underwent oral and maxillofacial ambulatory surgery under dexmedetomidine at the University of Navarra Clinic from February 2013 to November 2014. According to the loading dose the patients were grouped into 3 categories:<0.5, 0.5, and>0.5μg/kg-1.

Optimal level of sedation was defined as bispectral index<85. Data were analyzed using survival analysis techniques. Vasoactive drugs requirements was evaluated using exact logistic regression.

RESULTS:
Eighty-one patients were evaluated. Hazard ratios for patients in 0.5 and >0.5μg/kg-1 loading dose categories for achieving a bispectral index<85 were 1.5 (95% CI 0.9, 2.6) and 1.8 (95% CI 0.8, 3.9), respectively, compared with the lowest category. Five patients (6.2%) required atropine for bradycardia. Patients in the group>0.5μg/kg-1 showed greater risk of requiring atropine compared with the group<0.5μg/kg-1 (odds ratio 2.2; 95% CI 0.03, 183).

CONCLUSION:
Loading dose of dexmedetomidine>0.5μg/kg-1 appears minimize the time to achieve and maintain an optimal level of sedation during the first 60min of procedure. Further investigation to elucidate the association between loading dose of dexmedetomidine and subsequent atropine requirements may be warranted.

CITA DEL ARTÍCULO  Rev Esp Anestesiol Reanim. 2016 Nov 5. pii: S0034-9356(16)30142-6. doi: 10.1016/j.redar.2016.08.005

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra