Intraocular lens dislocation and tube shunt in the posterior chamber: a case report

Moreno-Montañés J(1), Velázquez-Villoria A(2), Sabater AL(3), Salinas-Alamán A(4).

(1) Department of Ophthalmology, Clínica Universidad de Navarra, Universidad de Navarra, Avda. Pio XII, 36-31008, Pamplona, Spain.
(2) Department of Ophthalmology, Clínica Universidad de Navarra, Universidad de Navarra, Avda. Pio XII, 36-31008, Pamplona, Spain.
(3) Department of Ophthalmology, Clínica Universidad de Navarra, Universidad de Navarra, Avda. Pio XII, 36-31008, Pamplona, Spain.
(4) Department of Ophthalmology, Clínica Universidad de Navarra, Universidad de Navarra, Avda. Pio XII, 36-31008, Pamplona, Spain.

Revista: BMC Ophthalmology

Fecha: 21/06/2015

Oftalmología

BACKGROUND:
To describe management of a case of intraocular lens (IOL) and capsular bag (CB) dislocation in an eye with an Ahmed glaucoma valve in the posterior chamber.

CASE PRESENTATION:
A 75-year-old pseudophakic man with open-angle glaucoma and diabetic retinopathy developed neovascular glaucoma. After two intravitreous injections of bevacizumab and panretinal photocoagulation were administered, the new vessels regressed. However, goniosynechiae were observed over 360° of the angle. An Ahmed glaucoma valve model FP7 was implanted with the tube in the posterior chamber with adequate intraocular pressure control. Nineteen years after cataract surgery, when the IOL-CB complex became dislocated, they were sutured transclerally to the sulcus without Ahmed glaucoma valve modification. After a coughing episode, the vitreous pushed the IOL-CB complex forward and the tube was behind the IOL-CB complex. A 25-gauge posterior vitrectomy was performed, and the tube was returned to in front of the optic of the IOL using a forceps tip through a sclerotomy.

CONCLUSION:
This case suggested that management of IOL-CB dislocation can modify glaucoma shunt function. A complete pars plana vitrectomy may be required in order to reposition the dislocated IOL-CB complex in the presence of a posterior chamber drainage tube implant.

CITA DEL ARTÍCULO  BMC Ophthalmol. 2015 Jun 21;15(1):63. doi: 10.1186/s12886-015-0046-7.

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra