Intensive training program for ultrasound diagnosis of adnexal masses: protocol and preliminary results

Alcázar JL, Díaz L, Flórez P, Guerriero S, Jurado M.
Department of Obstetrics and Gynecology, Clínica Universidad de Navarra, School of Medicine, University of Navarra, Pamplona, Spain

Revista: Ultrasound & Ginecology Obstetrics

Fecha: 18/02/2013

Ginecología y Obstetricia

OBJECTIVE
To assess the feasibility of a specific training program for ultrasound diagnosis of adnexal masses.

METHODS
A two-month intensive training program was developed. Program protocol consisted of one-day intense theoretical course focused on clinical and ultrasonography issues related to adnexal masses and ovarian cancer followed by a four-week real-time ultrasound training in a reference center (about 25-30 adnexal masses evaluated per month) and a final four-week period for off-line assessment of 3D volumes from adnexal masses. In this later period the trainee evaluated five sets of 100 3D-volumes each. 3D-volumes contained gray-scale and power Doppler information and the trainee was provided with clinical data of each case (patient's age, menopausal status and complaints). 3D-volumes were from masses surgically removed and histologic diagnosis was available or from masses followed-up until resolution. After each set assessment, trainee's diagnostic performance was calculated (sensitivity and specificity) and then the trainee evaluated with the trainer each mass incorrectly classified. The objective was to achieve a sensitivity > 95% and specificity > 90%. LC-CUSUM graphics were plotted to assess the learning curve for trainees.

RESULTS
One trainer and two trainees with very low experience on gynecological ultrasound (one gynecologist and one radiologist) participated in this study. LC-CUSUM graphics showed that competence was achieved after 170 examinations. The objectives for diagnostic performance were achieved after the second set of 3D volumes (200 cases) for each trainee.

CONCLUSIONS
The proposed training program seems feasible. High diagnostic performance can be achieved after 200 cases analyzed and it is maintained after.

CITA DEL ARTÍCULO 2013 Feb 18. doi: 10.1002/uog.12440

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra