Publicaciones científicas

Generation in plasma of a fast-acting inhibitor of plasminogen activator in response to endotoxin stimulation

Colucci M, Paramo JA, Collen D.

Revista: The Journal of Clinical Investigation

Fecha: 01/03/1985

Hematología y Hemoterapia

Endotoxin producing bacteria cause disseminated intravascular coagulation (DIC); however, the mechanism of endotoxin action in man is still unclear. Impairment of the fibrinolytic system has been suggested as a contributing mechanism.

A single injection of Escherichia coli lipopolysaccharide in rabbits resulted in a marked and prolonged increase of the levels of a fast-acting inhibitor of plasminogen activator (PA-inhibitor) in plasma (from 3.9 +/- 0.7 to 41 +/- 13.2 U/ml after 3 h). Gel filtration studies indicated that inhibition of human tissue-type plasminogen activator (t-PA) by rabbit plasma is accompanied by a change in the elution profile of the activator compatible with the formation of an enzyme-inhibitor complex with an apparent molecular weight of 100,000. Injection of human t-PA (1,500 IU/kg body wt) in endotoxin treated animals resulted in very fast inhibition of t-PA and formation of a similar complex. The half-life of circulating PA-inhibitor activity in rabbits was about 7 min as estimated by donor receiver plasma transfusion experiments. Stimulation of cultured human endothelial cells with endotoxin resulted in enhanced rate of accumulation of PA-inhibitor activity in the culture medium (two- to sevenfold increase). In five patients with septicemia, markedly increased levels of PA-inhibitor (14.3 +/- 15.5 U/ml) as compared with control subjects (1.3 +/- 0.7 U/ml) were observed in plasma. A very strong correlation (r = 0.98) was found between inhibition of t-PA and of urokinase in all conditions, suggesting that this fast-acting inhibitor reacts with both plasminogen activators.

These data suggest that the appearance of this fast-acting PA-inhibitor is very sensitive to endotoxin stimulation. The marked increase in the level of PA-inhibitor in blood may contribute to the pathogenesis of DIC in septicemia.

CITA DEL ARTÍCULO  J Clin Invest. 1985 Mar;75(3):818-24

tal vezLE INTERESE

¿QUÉ TECNOLOGÍA UTILIZAMOS?

La Clínica es el hospital privado con mayor dotación tecnológica de España, todo en un único centro.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

NUESTROS
PROFESIONALES

Los profesionales de la Clínica realizan una labor continuada de investigación y formación, siempre en beneficio del paciente.

Imagen profesionales de la Clínica Universidad de Navarra

POR QUÉ VENIR
A LA CLÍNICA

Conozca por qué somos diferentes a otros centros sanitarios. Calidad, rapidez, comodidad y resultados.

Imagen del edificio de la Clínica Universidad de Navarra