Transvaginal color Doppler assessment of venous flow in adnexal masses

Alcázar JL [SP], López-García G.
Department of Obstetrics and Gynecology, Clínica Universitaria de Navarra, School of Medicine, University of Navarra, Pamplona, Spain.

Magazine: Ultrasound in Obstetrics & Gynecology

Date: May 1, 2001

Gynaecology and Obstetrics

OBJECTIVE
To analyze the usefulness of transvaginal color Doppler assessment of venous flow in the differential diagnosis of adnexal masses.

MATERIAL AND METHODS
Ninety-one consecutive patients (mean age: 46.6 years, range: 16-81 years) diagnosed as having an adnexal mass were evaluated by transvaginal color Doppler sonography prior to surgery. Color Doppler was used to detect and analyze the flow velocity waveform from arterial and venous blood flow within the tumor. For arterial signals the resistance index and peak systolic velocity, and for veins the maximum venous flow velocity, were calculated. Receiver operator characteristic curves were plotted to determine the best venous flow velocity cut-off. According to our previous study using arterial Doppler, a tumor was considered as malignant when flow was detected and the lowest resistance index was < or = 0.45. Using venous Doppler a mass was considered as malignant when flow was detected and the venous flow velocity was > or = the best cut-off found on the receiver operator characteristic curve. Definitive histopathological diagnosis was obtained in all cases. Sensitivity, specificity, positive predictive value and negative predictive value for B-mode morphology (evaluation performed according to Sassone's scoring system), arterial Doppler, venous Doppler, and a combination of both arterial and venous Doppler were calculated.

RESULTS
Twenty-five masses (27.5%) were malignant and 66 (72.5%) benign. Arterial and venous flow was found more frequently in malignant than in benign masses (92% vs. 41% (P < 0.001) and 72% vs. 21% (P < 0.001), respectively). The resistance index was significantly lower in malignant tumors (0.42 vs. 0.60, P = 0.0003). No differences were found in peak systolic velocity. Venous flow velocity was significantly higher in malignant masses (18.1 cm/s vs. 8.9 cm/s, P = 0.0006). The best cut-off of venous flow velocity was 10 cm/s. Sensitivity, specificity, positive predictive value and negative predictive value for morphology, arterial Doppler, venous Doppler, and the combination of both arterial and venous Doppler were 92%, 71%, 45%, 96%; 76%, 95%, 87%, 91%; 68%, 94%, 81%, 89%; and 88%, 91%, 79%, 95%, respectively.

CONCLUSIONS
Our results indicate that preoperative evaluation by venous flow assessment of adnexal masses may be useful to discriminate between malignant and benign tumors.

CITATION  Ultrasound Obstet Gynecol. 2001 May;17(5):434-8

you maybe interested

WHAT TECHNOLOGY
DO WE USE?

The Clínica is the greater private hospital with technological equipment of Spain, all in a single center.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OUR
PROFESSIONALS

The professionals of the Clínica perform continuous research and training, always to the benefit of the patient.

Imagen profesionales de la Clínica Universidad de Navarra

WHY CHOOSE
THE CLINICA?

Learn why we are different from other healthcare centers. Quality, speed, comfort and results.

Imagen del edificio de la Clínica Universidad de Navarra