Interaction of 2-Gy equivalent dose and margin status in perioperative high-dose-rate brachytherapy

Martínez-Monge R, Cambeiro M [SP], Moreno M [SP], Gaztañaga M, San Julián M, Alcalde J [SP], Jurado M.
Department of Oncology, Clínica Universitaria de Navarra, University of Navarre, Navarre

Magazine: International Journal of Radiation Oncology, Biology, Physics

Date: Mar 15, 2011

Orthopedic Surgery and Traumatology [SP] Otorhinolaryngology Radiation Oncology Gynaecology and Obstetrics

PURPOSE
To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2).

PATIENT AND METHODS
Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clínica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy.

RESULTS
no dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy.

CONCLUSIONS
Two-gray equivalent doses ?70 Gy may compensate the effect of close margins ?1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ?50 Gy with PHDRB alone.

CITATION Int J Radiat Oncol Biol Phys. 2011 Mar 15;79(4):1158-63

you maybe interested

WHAT TECHNOLOGY
DO WE USE?

The Clínica is the greater private hospital with technological equipment of Spain, all in a single center.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OUR
PROFESSIONALS

The professionals of the Clínica perform continuous research and training, always to the benefit of the patient.

Imagen profesionales de la Clínica Universidad de Navarra

WHY CHOOSE
THE CLINICA?

Learn why we are different from other healthcare centers. Quality, speed, comfort and results.

Imagen del edificio de la Clínica Universidad de Navarra