Independent component analysis as a tool to eliminate artifacts in EEG: a quantitative study

Iriarte J, Urrestarazu E [SP], Valencia M, Alegre M [SP], Malanda A, Viteri C [SP], Artieda J [SP].
Clinical Neurophysiology Section, Clínica Universitaria, University of Navarra, Pamplona, Spain

Magazine: Journal of Clinical Neurophysiology

Date: Aug 1, 2003

Neurology [SP] Neurophysiology [SP]

Independent component analysis (ICA) is a novel technique that calculates independent components from mixed signals. A hypothetical clinical application is to remove artifacts in EEG. The goal of this study was to apply ICA to standard EEG recordings to eliminate well-known artifacts, thus quantifying its efficacy in an objective way. Eighty samples of recordings with spikes and evident artifacts of electrocardiogram (EKG), eye movements, 50-Hz interference, muscle, or electrode artifact were studied. ICA components were calculated using the Joint Approximate Diagonalization of Eigen-matrices (JADE) algorithm. The signal was reconstructed excluding those components related to the artifacts. A normalized correlation coefficient was used as a measure of the changes caused by the suppression of these components. ICA produced an evident clearing-up of signals in all the samples. The morphology and the topography of the spike were very similar before and after the removal of the artifacts. The correlation coefficient showed that the rest of the signal did not change significantly. Two examiners independently looked at the samples to identify the changes in the morphology and location of the discharge and the artifacts. In conclusion, ICA proved to be a useful tool to clean artifacts in short EEG samples, without having the disadvantages associated with the digital filters. The distortion of the interictal activity measured by correlation analysis was minimal.

CITATION J Clin Neurophysiol. 2003 Jul-Aug;20(4):249-57

you maybe interested

WHAT TECHNOLOGY
DO WE USE?

The Clínica is the greater private hospital with technological equipment of Spain, all in a single center.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OUR
PROFESSIONALS

The professionals of the Clínica perform continuous research and training, always to the benefit of the patient.

Imagen profesionales de la Clínica Universidad de Navarra

WHY CHOOSE
THE CLINICA?

Learn why we are different from other healthcare centers. Quality, speed, comfort and results.

Imagen del edificio de la Clínica Universidad de Navarra