GI-RADS reporting system for ultrasound evaluation of adnexal masses in clinical practice: a prospective multicenter study

Amor F, Alcázar JL [SP], Vaccaro H, León M, Iturra A.
Centro Ecografico Ultrasonic Panoramico, Santiago, Chile.

Magazine: Ultrasound in Obstetrics & Gynecology

Date: Oct 1, 2011

Gynaecology and Obstetrics

To assess the clinical usefulness of a structured reporting system based on ultrasound findings for management of adnexal masses.

This was a prospective multicenter study comprising 432 adnexal masses in 372 women (mean age, 44.0 (range, 13-78) years) over a 36-month period. Ninety-three (25%) women were postmenopausal and 279 (75%) women were premenopausal. Patients were evaluated with transvaginal ultrasound by one of three examiners expert in gynecological ultrasound. Reporting was provided to referring clinicians according to the Gynecologic Imaging Report and Data System (GI-RADS) classification. A predetermined management protocol was offered to referral clinicians. It was suggested that patients classified as GI-RADS 2 be managed with follow-up scan, patients classified as GI-RADS 3 undergo laparoscopic surgery and patients classified as GI-RADS 4 or 5 be referred to a gynecologic oncologist. Definitive histologic diagnosis was available in 370 cases and 62 additional cases were considered as benign because of spontaneous resolution during follow-up. These outcomes were used as the gold standard for calculating the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+) and negative likelihood ratio (LR-) of GI-RADS classification for identifying adnexal masses at high risk of malignancy, considering GI-RADS 4 and 5 as being malignant.

Of the 432 tumors, 112 were malignant and 320 benign. The GI-RADS classification rate was as follows: GI-RADS 2, 92 (21%) cases; GI-RADS 3, 184 (43%) cases; GI-RADS 4, 40 (9%) cases; GI-RADS 5, (27%) 116 cases. Sensitivity for this system was 99.1% (95% CI, 95.1-99.8%), specificity was 85.9% (95% CI, 81.7-89.3%), LR+ was 7.05 (95% CI, 5.37-9.45) and LR- was 0.01 (95% CI, 0.001-0.07). PPV and NPV were 71.1% and 99.6%, respectively.

The GI-RADS reporting system performed well in identifying adnexal masses at high risk of malignancy and seems to be useful for clinical decision-making. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

CITATION  Ultrasound Obstet Gynecol. 2011 Oct;38(4):450-5. doi: 10.1002/uog.9012.

you maybe interested


The Clínica is the greater private hospital with technological equipment of Spain, all in a single center.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra


The professionals of the Clínica perform continuous research and training, always to the benefit of the patient.

Imagen profesionales de la Clínica Universidad de Navarra


Learn why we are different from other healthcare centers. Quality, speed, comfort and results.

Imagen del edificio de la Clínica Universidad de Navarra