Fat mass by air-displacement plethysmography and impedance in obese/non-obese children and adolescents

Azcona C, Köek N, Frühbeck G.
Paediatric Endocrinology Unit, Department of Paediatrics, Clinica Universitaria, Pamplona, Spain. 

Magazine: International Journal of Paediatric Obesity

Date: Jan 1, 2006

Pediatrics [SP] Endocrinology and Nutrition [SP]

Objective
To determine the level of agreement between measurements of body composition by air-displacement plethysmography (ADP) and bioelectrical impedance analysis (BIA) in obese/non-obese children and adolescents.

Methods
Fat mass (FM) and fat free mass (FFM) were measured by ADP using the BOD-POD system and foot-to-foot BIA in 187 children and adolescents (75 males and 112 females, aged 5 to 22 years). Obesity was defined as a percentage FM (determined by BOD-POD), as a percentage (%) higher than 25%-35%. Sixty-four subjects were obese and 123 non-obese.

Results
Lin's Concordance Coefficient (Rc) between estimates of FM (%) and FFM (kg) was 0.79 (95% CI: 0.73; 0.83) by BIA and 0.96 (95% CI: 0.95; 0.97) by ADP. For the group of patients as a whole, the mean difference (p < 0.001) between methods (the BIA measurement minus the ADP measurement) was -3.39 (95% CI: -4.13; -2.65) for FM (%) and 1.54 (95% CI: 1.10; 1.98) for FFM (kg) (p < 0.001). The limits of agreement were -13.70; 6.90 for FM (%) and 1.40; 7.60 for FFM (kg). In the obese group, the mean difference between methods was -5.01 (95% CI: -6.21; -3.81) for FM (%) and 2.58 (95% CI: 3.45; 1.71) for FFM (kg) (p < 0.001). In the non-obese group, these mean differences were 2.49 (95% CI: -3.41; -1.57) and 0.96 (95% CI: 1.43; 0.50), respectively (p < 0.001).

Conclusions
Compared with ADP, foot-to-foot BIA overestimates FFM and underestimates FM in obese and non-obese children of either sex. ADP and BIA estimates of FFM and FM are highly correlated for both obese/non-obese children. However, the large limits of agreement suggest that these methods should not be used interchangeably.

CITATION  Int J Pediatr Obes. 2006;1(3):176-82.

tal vezLE INTERESE

WHAT TECHNOLOGY
DO WE USE?

The Clínica is the greater private hospital with technological equipment of Spain, all in a single center.

Imagen de un PET, tecnología de vanguardia en la Clínica Universidad de Navarra

OUR
PROFESSIONALS

The professionals of the Clínica perform continuous research and training, always to the benefit of the patient.

Imagen profesionales de la Clínica Universidad de Navarra

WHY CHOOSE
THE CLINICA?

Learn why we are different from other healthcare centers. Quality, speed, comfort and results.

Imagen del edificio de la Clínica Universidad de Navarra